Control Cables:Used in interconnection of process control, communication and panel control systems.
Electrical Wiring Cables:Used for electric power, lighting & internal wiring. |
Used in connection of power supply to residential, commercial & industrial units. |
Used in data acquisition systems, computer networking, PA systems, digital control/measuring & communication systems. Specially designed to transmit signals without any external interference. |
Used to extend thermocouple circuits from the sensor to reference unit. |
|
PVC / XLPE insulated cables conforming to IS:1554-I / IS:7098-I, BS:6346, IEC:60502, BS:5467, BS:7846, IEC:60227, BS:6004, BS:6500, IS:694 and Customer specific requirements.
Control Cables: Generally with conductor sizes 1.5 /2.5 / 4.0 sq.mm.
Electrical Wiring Cables: Single Core cables upto 630 sq.mm.
Multi Core cables upto 50 sq.mm.
|
PVC / XLPE insulated cables conforming to IS:1554-I / IS:7098-I, BS:6346,IEC:60502, BS:5467, BS:7846 and Customer specific requirements.
Single Core cables upto 1000 sq.mm.
Multi Core cables upto 400 sq.mm.
|
Generally manufactured with conductor sizes 0.5 / 0.75 / 1.0 / 1.5 sq.mm. Conforming to BS:5308-I & II, IEC-189, VDE 0815, IEC:60227, BS:7846 and Customer specific requirements.
|
Generally manufactured with conductor sizes 16, 18 & 20 AWG. Conforming to IS:8784, BS:4937, IEC-584, ANSI:MC:96.1, DIN, JIS and Customer specific requirements.
|
|
Conductor: Solid / stranded / flexible copper, circular / shaped, copper / aluminium.
Insulation: PVC – GP / HR; XLPE, LSZH,EPR
Inner Sheath: PVC – GP / HR / FR / FRLS; LSZH
Armour (for armoured cables): Galvanised steel wire / strip / tape / double tape or aluminium wire
Outer Sheath: PVC – GP / HR / FR / FRLS; LSZH
|
Conductor: Solid / stranded, circular / shaped, copper / aluminium.
Insulation: PVC –GP / HR; XLPE, LSZH,EPR
Inner Sheath: PVC – GP / HR / FR / FRLS; LSZH
Armour (for armoured cables): Galvanised steel wire / strip / tape or aluminium wire.
Outer Sheath: PVC – GP / HR / FR / FRLS; LSZH
|
Conductor: solid / stranded / flexible copper (bare / tinned)
Insulation: PVC – GP / HR; PE, XLPE, LSZH, EPR
Shielding: Individual & overall or overall screen only by Al-mylar tape / copper tape / copper wire braid
Inner Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH, EPR
Armour (for armoured cables): Galvanised steel wire / strip / tape / double tape / braid
Outer sheath: PVC – GP / HR / FR / FRLS; PE, LSZH
|
Conductor: Solid / stranded; Type: KX, VX, TX, JX, EX, R or S (SX)
Insulation: PVC – GP / HR; PE, XLPE, LSZH, EPR
Shielding: Individual & overall or overall screen only by Al-mylar tape / copper tape / copper wire braid
Inner Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH,EPR
Armour (for armoured cables): Galvanised steel wire / strip / braid
Outer Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH
|