Control Cables:Used in interconnection of process control, communication and panel control systems. Electrical Wiring Cables: Used for electric power, lighting & internal wiring.
|
Used in connection of power supply to residential, commercial & industrial units.
|
Used in data acquisition systems, computer networking, PA systems, digital control / measuring & communication systems. Specially designed to transmit signals without any external interference.
|
Used to extend thermocouple circuits from the sensor to reference unit.
|
|
PVC / XLPE insulated cables conforming to IS:1554-I / IS:7098-I,BS:6346, IEC:60502, BS:5467,BS:7846, IEC:60227, BS:6004, BS:6500, IS:694 and Customer specific requirements.
Control Cables: Generally with conductor sizes 1.5 /2.5 / 4.0 sq.mm. Electrical Wiring Cables: Single Core cables upto 630 sq.mm.
Multi Core cables upto 50 sq.mm.
|
PVC / XLPE insulated cables conforming to IS:1554-I / IS:7098-I,BS:6346,IEC:60502, BS:5467,
BS:7846 and Customer specific requirements. Single Core cables upto 1000 sq.mm. Multi Core cables upto 400 sq.mm.
|
Generally manufactured with conductor sizes 0.5 / 0.75 / 1.0 / 1.5 sq.mm. Conforming to BS:5308-I & II, IEC-189, VDE 0815, IEC:60227, BS:7846 and Customer specific requirements.
|
Generally manufactured with conductor sizes 16, 18 & 20 AWG. Conforming to IS:8784, BS:4937, IEC-584, ANSI:MC:96.1, DIN, JIS and Customer specific requirements.
|
|
Conductor: Solid / stranded / flexible copper, circular / shaped, copper / aluminium.Insulation: PVC – GP / HR; XLPE, LSZH, EPR
Inner Sheath: PVC – GP / HR / FR / FRLS; LSZH Armour (for Armoured Cables): Galvanised steel wire / strip / tape / double tape or aluminium wire.
Outer Sheath: PVC – GP / HR / FR / FRLS; LSZH
|
Conductor: Solid / stranded, circular / shaped, copper / aluminium. Insulation: PVC –GP / HR; XLPE, LSZH, EPRInner Sheath:
PVC – GP / HR / FR / FRLS; LSZH Armour (for Armoured Cables): Galvanised steel wire / strip / tape or aluminium wire. Outer Sheath: PVC – GP / HR / FR / FRLS; LSZH
|
Conductor: solid / stranded / flexible copper (bare / tinned)
Insulation: PVC – GP / HR; PE, XLPE, LSZH, EPR Shielding:
Individual & overall or overall screen only by Al-mylar tape / copper tape / copper wire braid Inner Sheath: PVC – GP / HR / FR / FRLS;PE, LSZH, EPR Armour (for Armoured Cables):
Galvanised steel wire / strip / tape / double tape / braid Outer Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH, EPR
|
Conductor: Solid / stranded; Type: KX, VX, TX, JX, EX, R or S (SX) Insulation: PVC – GP / HR; PE, XLPE, LSZH, EPR Shielding:
Individual & overall or overall screen only by Al-mylar tape / copper tape / copper wire braid Inner Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH, EPR Armour (for Armoured Cables):
Galvanised steel wire / strip / braid Outer Sheath: PVC – GP / HR / FR / FRLS; PE, LSZH, EPR
|